DATA CENTER INFRASTRUCTURE

Infrastructure    Security    Network Diagram   Network Providers

 


Data Center Infrastructure

Tier1 Data Center Facilities include the following:

Network Operations Center monitoring, staffed 24x7x365 Access controlled by access card and biometric scan, with motion detecting surveillance system Dual, fully redundant Gigabit Ethernet connections to SAVVIS and to Internap Network routing optimization technology for enhanced network performance 13,000+ square feet of raised floor data center space with customized colocation offerings Highly stable, controlled, raised-floor environment with redundant power delivery, back-up generators, fire detection and suppression, HVAC, humidity control and physical security Operating Environment Set at 68°F (20°C) with 45% humidity and a variation of no more than 8°F of temperature, or 4% in humidity Fire Detection multi-zone above and below raised floor monitored internally by the NOC Highly trained and experienced staff available for professional services and remote hands assistance .

 

Power   

Electrical power from Colorado's Xcel Energy is delivered from dual feeds from the Surrey Ridge substation. The electric service in the building is connected to a parallel redundant Powerware UPS, which delivers conditioned power to the data center via a Starline Bussway system. This system eliminates the need for traditional power distribution units (PDU's) and enhances the reliability of the system as well as making "A" and "B" power available to every computer equipment cabinet.
UPS           : Dual Powerware 160KVA.
Generator   :Cummings 1000KW diesel generator with 7-day fuel reserve.
Distribution :Starline Bussway provides A/B power to all cabinets.
ATS           :1600 Amp Automatic Transfer Switch.

 

Environmental

Cooling and Humidity
Controlled by six (6) 30-ton Data Aire air handling units (AHUs) providing N+2 redundancy. The AHus are completely redundant (N+2) as only 3 of the AHU's are needed to properly cool the data center if it were fully loaded with equipment.
Operating Environment  :Set at 68°F (20°C) with 45% humidity and a variation of no more than 4°F of temprature, or 4% in humidity.



Fire Detection and Fire Suppression

Fire Detection
Multi-zone above and below raised floor monitored internally by the NOC and externally by Honeywell. The data center has sensors installed both above and below the raised floor to detect gases that rise with the airflow in the center as well as heavy gases that tend to settle under the floor.
Fire Suppression
Dry pipe pre-action system that will not pressurize until two (2) mointors are triggered. The fire suppression system is a pre-action, dry pipe which would discharge water only from the appropriate locations if the heat in the data center increases enough to trigger a fire sprinkler head. The discharge of a sprinkler would signal the emergency power off switch which would simultaneously turn off the electrical power to the entire data center room.


Operations Center

Staffing
24 x 7 x 365.
Personnel
NOC personnel are well trained with CCNA, CCNP, CCSA, CCSE, MCSE and other certifications.
Monitor
The Network, facilities, and customers are monitored continuously by best of breed monitoring tools.
Remote Hands
Available for assisting customers.


 

 